OEM PRODUKTE

Unsere Produkte aus diesem Bereich werden hier, mit Rücksicht auf unsere OEM Kunden, nicht detailiert gezeigt und beschrieben.

BERÜHRUNGSLOSE ZUTRITTSKONTROLLE

BONNEL TECHNOLOGIE has been delivering access technology based on RFID for over 20 years. We design, develop and professionally manufacture wireless locking solutions for our clients in the Czech Republic and Europa wide.

Why to use them?

  • Safety
  • Flexibility (various numbers of users and facilities)
  • Maintenance free (no battery or contact)
  • Easy installation (pre-configured system, no dangerous line voltage, suitable for non-professionals)
  • Comprehensive (use for doors, gates, windows, elevators, machines operation etc.)
  • Support (BONNEL service center offers support in Czech, German and English)

Where to use them?

  • Blocks of flats
  • Public office buildings
  • Hospitals and schools
  • Warehouses and storage facilities
  • Private houses (entrance doors, garage doors, lighting etc.)
  • Others

Read more about our transponder systems HERE.

Ask our Sales team for details HERE

TRANSSYS Transponder System

KeyManager.jpeg
Lokaj.jpeg
KeyManager_2022.png
previous arrow
previous arrow
next arrow
next arrow

Transponder-System TRANSSYS 2000

Contactless operating of doors, gates, alarm devices and machines (RFID)


TRANSSYS 2000 is a modern, safe and comfortable system for contactless switching of appliances (locks, garage door drives, illumination, alarm devices etc.). TRANSSYS 2000 will give you the flexibility and independence that no mechanical switching system can offer. Despite the manifold possibilities, the application is easy to install: You will get a completely pre-configured system, which is ready to use directly after installation. The system is based on the contactless transponder principle so the keys are non-wearing and maintenance-free (no battery or contact). With the help of the Master-Key (card) the system can be reprogrammed very easily and existent keys can be added or removed.


  • Contactless electric switching
  • Maintenance-free electronic keys (no battery or contact) in key tag look
  • Control- and reading unit are also available as one integrated device for installation into a standard flush-mounted box (to be used in the safe area)
  • Intervention or destruction of the reading unit does not result in a switching signal of the control unit (i.e. a door will not be opened)
  • Length of connection wire between reading unit and control unit is 2.5 m, the wire can be shortened according to individual requirements
  • Easy to find and to operate (blinking LED) also at darkness
  • Key-code with more than 4.3 billion possibilities ensures a maximum of security
  • Master-key as identification key for individual customization of the system and for (de-) registering of keys
  • If required, one master-key can control multiple TRANSSYS 2000 systems (suitable i.e. within one building or property)
  • All parameters are permanently saved and will not be lost in case of a possible electrical power outage
  • Hierarchical locking system: One electronic key can be registered at different locks (i.e. entrance, alarm system, garage, PC-access, garden irrigation) and handle different devices
  • All-purpose switch (potential-free relay contact as output, circuit time adjustable as 1-25 s or permanent on / off)
  • Operation as relay circuit with permanent on / off permits i.e. to switch electric consumer or to arm alarm devices
  • Easy installation also suitable for non-professionals, no dangerous line voltage

  • Identification medium inside a key tag
  • Operating frequency 125 kHz
  • Reading distance approx. 5 cm
  • Power-supply 9-12 V AC/DC, i.e. bell transformer 12 V / 1A
  • Current consumption peak 250 mA, average 40 mA
  • Relay contact 30 V / 1 A (shutter)
  • Circuit time adjustable 1-25 s or permanent on / off, delivery status 3 s
  • Number of keys max. 100 (larger systems available)
  • Dimensions control unit: Diameter 60 mm, height 22 mm
  • Dimensions reading unit: Diameter 83 mm, height 15 mm
  • Length of connection wire between reading unit and control unit: 2.5 m (can only be shortened)
  • Protection class reading unit: IP 44 (after installation)
  • Protection class control unit IP 20
  • Operating temperature range reading unit -30°C to 60°C
  • Operating temperature range control unit 0°C to 40°C, dry interior space
  • CE mark

  • 1 control unit (interior installation, i.e. in a flush-mounted box)
  • 1 reading unit (exterior installation, well accessible)
  • 1 fastening-parts kit
  • 1 master-key (in key tag look, red, for (de-) registering the keys)
  • 4 electronic keys (in key tag look)

Since 2023, all STANDARD and CRYPTO variants were discontinued.
Only the SUPER variant is now offered.

TRANSSYS 2000 SUPER - max. 2000 keys


1. Is TRANSSYS suitable for a small family house as well as for a big block of flats (housing estate)?
YES, CERTAINLY.

2. Can we choose a number of access units and select the doors in which they will be installed?
YES. TRANSSYS can be used for the entrance door and for doors of shared rooms, such as a laundry or a lift. Upon customer´s wish, all the doors can be unlocked with one key.

3. What should I do if…

a) …I loose my key fob?
If you do not have a Key Manager for your small system in the family house, please reset the unit completely using the master key (see the manual). You will cancel all the registered keys, including the lost one. Unfortunately, you cannot deregister only one key since it is not not available physically. Then, register all the keys – transponders which you wish to use in the system, including a new, spare key.
If you have a Key Manager (key administration system) available, your adminstrator will make the so-called delete key from the data stored in the computer. It is a data copy of the lost key fob which cannot unlock the door but it can delete the data of the lost key in the unit.

b) …I want to add a new key fob?
A new key fob can be added whenever you wish to until you reach the limit number of your TRANSSYS transponder system.

c) …the reading unit does not work?
If the control LED is not blinking/signalling red on the reading unit, please check the power supply. This LED blinking signal can be switched off in the unit configuration.

If the reading unit does not respond to a key fob, please check the conductivity between the control unit and the reading unit.
If the reading unit responds/ registers the key fob with a quickly blinking LED signal, the key fob is defect or it has not been registered yet.
If the reading unit registers the key fob correctly but it does not unlock the door, please check the power supply to the electrical lock, respectively a cable between the control unit and and the latch.
If the reading unit registers the key fob correctly and the power supply is fine but it does not unlock the door, please send your control unit to our service team (your seller) for inspection.

d) ...your Key Manager (key fob administration system) does not work?
Contact our service team at: Diese E-Mail-Adresse ist vor Spambots geschützt! Zur Anzeige muss JavaScript eingeschaltet sein!

4. Can you train partner service companies or sellers of locking systems?
Service and maintenance companies which install locking systems or lifts in buildings and sellers of locking systems can request a professional training for the TRANSSYS transponder system directly in our development and production plant in Cheb, Czech Republic. We can also offer an online workshop (a skype call). Contact our service team at Diese E-Mail-Adresse ist vor Spambots geschützt! Zur Anzeige muss JavaScript eingeschaltet sein!


 It is necessary to allow opening the door from inside by emergency key or handle in a case of fire when using this system.

Please use our Contact form to order your TRANSYSS.


 

zip-1KeyManager Installer 1.0.0 Beliebt
 

SCHLIESSTECHNIK

Unsere Produkte aus diesem Bereich werden hier, mit Rücksicht auf unsere OEM Kunden, nicht detailiert gezeigt und beschrieben.